Tuesday, April 16, 2019
Lab Report on TLC analisys of Analgestic Drugs Essay Example for Free
Lab Report on tender loving care analisys of Analgestic Drugs EssayIn this experiment, thin-layer chromatography (TLC) was employ to charm the composition of various over-the-counter (OTC) analgesics Anacin, Bufferin, Excedrin, and Tylenol. The TLC menages were first viewed on a lower floor ultraviolet (UV) light and thence treated with iodine vapor in order to visualize the spotting. investigate SchemeInitially, sixteen capillary micropipets were created in order to spot the TLC plates. Two TLC plates were then obtained and marked with pencil for spotting. A line was drawn 1 cm from the bottom of each plate, and fin small, evenly spaced label were made along those lines (see manakin 1). Each mark indicated where a core group would be spotted.All compounds used were in solutions of 1g of each dissolved in 20 ml of a 5050 mixture of methylene chloride and ethanol. The first plate made was the elongation plate. Capillary micropipets were used to spot the first four mark s with acetaminophen, aspirin, caffeine, and salicylamide (in that order). (See figures 2-5 for chemical structures.)The last mark was spotted with a reference solution of all four chemicals. The second plate made was the sample plate. The first four marks were spotted with Anacin, Bufferin, Excedrin, and Tylenol. The fifth mark was spotted with a reference solution of all four drugs. Figure 1. Prepared TLC platesFigure 2. AcetaminophenFigure 3. AspirinFigure 4. CaffeineFigure 5. SalicylamideA information container was created with a wide-mouthed screwcap jar. It was filled with the development solvent, which was .5% glacial acetic acid in ethyl acetate, so that the solvent was approximately .5 cm deep.The first TLC plate was then carefully placed into the development container. Great care was interpreted to ensure that the plate went in evenly so that the solvent could rise evenly up the plate. one time the solvent front had reached approximately 1cm from the top of the plate, th e plate was removed, the solvent front was marked with a pencil, and the plate was allowed to dry.The second plate was then placed in the development chamber in the same expressive style as the first. Once the solvent front reached approximately 1cm from the top of the plate, the plate was removed, the solvent front was marked with a pencil, and the plate was allowed to dry. Each plate was then viewed under the UV light.Any spots that were seen were thin circled with a pencil, and their color was noted. The orders of elution (Rf values) were calculated by dividing the outer space from the baseline to the center of the spot by the distance from the baseline to the solvent front. After all observations and calculations were made, the plates were placed in a jar containing iodine.The jar was change with hands so that the iodine vaporized. The plates were then removed from the jar and observed. The reference and sample plates were then compared to determine which compounds the drugs on the sample plate contained. Data
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment